Video: Omron F3SG Dynamic Muting Demonstration Video


Dynamic Muting using Software Tool *** For more product information see: http://industrial.omron.us/en/products/catalogue/safety/safetysensors/safety_light_curtain/f3sg_ra/default.html 1. Go on line with the light curtain. 2. Select “Log In” button on the top of the window to bring up the Log In window. 3. Select Administrator radio button and enter password. If no password has been entered previously or the unit is just opened from the factory the default password is 0000. Then select the “OK’ button to close the window. 4. Select the “Recovery” button to execute factory default procedure. To default the light curtain back to factory defaults, select the “Reset to Factory Default Settings” button. Verify the procedure was complete by looking at the bottom of the window and it should state “Tool success to recovery sensor setting”. 5. Select “Top page” button at the top of the window to go back to the main page. 6. Select “Muting/Override” button under the Function Setting area of the software. This will get you into the Muting/Override window. 7. Verify that the Muting enable radio button is enabled. 8. Using the “Muting Mode” pull down select “Exit-Only Muting” function (This is the only option that can be demonstrated using the F3W-MA Muting Actuators). 9. Verify that the “Manual” radio button is selected. 10. Verify that the Muting Zone is the complete length of the light curtain. For the demo Bottom beam set to 1 and Top beam is set to 16. If you need to change this make sure to select “Confirm Zone” button. 11. Select “Dynamic muting” enable radio button. 12. Set “Measurement time” to 1.0 sec. using the slider bar. 13. If you choose to change the “Number of Allowable Beam selection, use the pull down to do so. 14. Select “Top page” button at the top of the window to go back to the main page. 15. Select “Lamp Setting” button of the software. This will get you into the Lamp Setting window. 16. Set Auxiliary Output for the following: Output Operation Mode = Muting/Override Information Inverted signal output = Disable Output pattern = ON 1 time 17. Set Lamp Output Red (Priority 1) for the following: Output Operation Mode = Safety output information Inverted signal output = Enable Output pattern = Solid-ON 18. Set Lamp Output Orange (Priority 2) for the following: Output Operation Mode = Muting/Override Information Inverted signal output = Disable Output pattern = ON-1 time 19. Set Lamp Output Green (Priority 3) for the following: Output Operation Mode = Safety output information Inverted signal output = Disable Output pattern = Solid-ON 20. Select the “Write configuration” button to write the settings to the light curtain. This will bring up a write configuration window. To initiate the write select the “Write” button. Settings will then transfer to the light curtain. 21. To activate the light curtain you can go to the “Monitor “ button on the top of the page or cycle power to the unit. 22. Test the system by moving various height objects thru the muting sensors the light curtain should turn on the muting lamp indicating the light curtain is in a muting condition and the objects should then be allowed to pass thru the light curtain without tripping the output. 23. If you send an object that gets larger in size as it passes thru the light curtain the output should then trip.


Ver mas videos relacionados

Chatea con nosotros !